Sensorless Vector PSV6 Series

200V Class

Rated Input Voltage:

1/4 – 3 HP
200 – 240VAC, +5% / -10%,
Single or Three Phase (1Ø or 3Ø)
50/60Hz + 5%.

5 – 10 HP
200 – 240VAC, +5% / -10%,
Three Phase (3Ø)
50/60Hz + 5%.

Rated Output Voltage:
200 – 230V + 10%, 3Ø
According to supply voltage.

psv6-big

PSV6 Series 230V Model Selection Table

HP Model kW kVA Output (A)
1/4 PSV6-03 0.2 0.6 1.6
1/2 PSV6-05 0.4 1.0 2.6
1 PSV6-10 0.75 1.6 4.0
2 PSV6-20 1.5 3.3 8.0
3 PSV6-30 2.2 4.5 11.0
5 PSV6-50 3.7 7.2 17.5
71/2 PSV6-75 5.5 9.1 24.0
10 PSV6-100 7.5 12.2 32

 

400V Class

Rated Input Voltage:
380 – 460VAC, +10%, 3Ø (only)
50/60Hz + 5%.

Rated Output Voltage:
380 – 460V + 10%, 3Ø
Corresponding to supply voltage.

PSV6 Series 460V Model Selection Table

HP Model kW kVA Output (A)
1/2 PSV6-051 0.4 1.1 1.5
1 PSV6-11 0.75 1.9 2.5
2 PSV6-21 1.5 3.0 3.8
3 PSV6-31 2.2 4.3 5.5
5 PSV6-51 4.0 6.8 8.6
71/2 PSV6-76 5.5 10.3 13
10 PSV6-101 7.5 12.7 16

Control Method:
Sine-wave pulse width modulation (PWM) control

Output Frequency Range:
0.1 – 360 Hz
To operate the beyond 50/60 Hz,
consult the motor manufacturer
about the maximum allowable speed

Frequency Accuracy:

Digital command:
+ 0.01% of the max. frequency

Analog command:
+ 0.1% (25C + 10C) of the max. frequency

Frequency Setting Resolution:

Digital: 0.1 Hz

Analog: Max. frequency/1000

V/F Characteristics:
V/F optionally variable,
V/F control (constant torque, reduced torque)
Sensorless vector control.
SLV selected, set carrier frequency more than 2.1kHz.

Overload Current Rating:
150%, 60 Seconds

Acceleration/Deceleration Time:
0.1 – 3000 sec. (linear/curve, accel./decel.),
Two stage accel./decel. setting available

Starting Torque:
00% or more – up to 3 HP
180% or more – above 3 HP
At the rated voltage when using a Hitachi standard 3-phase, 4-pole motor. (when selecting high starting torque flux vector control.)

Braking:

Dynamic Braking (without external resister)
Approx. 100% – up to 1 HP
Approx. 70% – 2 HP
Approx. 20% – above 2 HP

Dynamic Braking (with external resister)
Approx. 150% – up to 2 HP
Approx. 100% – above 2 HP
The braking torque at capacitive feedback is the average deceleration torque at the shortest deceleration (stoppage from 50 Hz) of the motor itself. It is not the continuous regenerative braking torque. And the average deceleration torque varies with motor loss. This value decreases when operating beyond 50/60 Hz. If a large regeneration torque is required, the optional braking resistor should be used.

DC Braking-
Operating frequency, time and braking force variable.

Input Signal:

Frequency Setting

Digital Operator Panel:
Up(1) and Down(2) keys/value setting keys.
Potentiometer:
Analog Setting
External signal:
0 ~ 10 VDC (input impedence 10k ohms),
4 ~ 20 mA (input impedence 250k ohms)
Potentiometer: 1k to 2k ohms, variable resistor
The frequency command is the maximum frequency at 9.8V for input voltage 0 – 10 VDC, or at 19.6 mA for input current ~ 20 mA. If this characteristic is not convenient, contact Polyspede.

Forward/Reverse/Run

Digital Operator Panel:
Run/Stop (Forward/Reverse run change by command)

External signal:
Forward RUN/STOP, Reverse RUN/STOP
Operation command available at terminal assignment
(1a/1b selectable)

Intelligent Input Terminals
FW (Forward run command), RV (reverse run command, CF1~CF4 (multi-stage speed setting), JG (jogging command), 2CH (2-stage acceleration/deceleration command), FRS (free run stop command), EXT (external trip), USP (USP function), SFT (soft lock), AT (analog current input select signal), RS (reset), PTC (thermal protection), DB (external DC braking command, SET (2nd setting selection), UP (remote control, acceleration), DWN (remote control, deceleration)

Output Signal:

Intelligent Output Terminal
RUN (running signal), FA1,2 (frequency arrival signal), OL (overload advance notice signal), OD (deviation signal at PID control), AL (alarm signal)

Frequency Monitor
PWM output: Select analog output frequency monitor,
analog output current monitor or digital output frequency monitor

Alarm Output Contact:
ON for the inverter alarm (1C contact output) (possible to change to OFF for the alarm)

Other Functions:
AVR function, curved acceleration/deceleration, upper/lower limiter, 16-stage speed, fine adjustment of start frequency, carrier frequency change (0.5 to 10 Kz) frequency jump, gain and bias setting, process incing, electronic thermal level adjustment, retry function history monitor, 2nd setting selection, auto tuning, Fan on/off selection PID control, carrier frequency change, frequency jump.

Protective Function:
Overcurrent, overvoltage, undervoltage, overload, extreme high/low temperature, CPU error, memory error, ground fault detection at startup, internal communication error, Electronic thermal, CT error

Environmental Conditions:

Ambient Operating: -10 ~ 50^(o)C
Storage Temperature: -20 ~ 70^(o)C
Humidity: 25 ~ 90 % RH (no condensation)
Vibration: 5.9 m/s^(2) (0.6G), 10 ~ 55 Hz
Location: Less than 1000 m of altitude or less, indoors (no corrosive gases or dust)

Color:
Munsell 8.5YR6.2/0.2, cooling fins in base aluminum.

Protective Structure:
IP20 (NEMA 1)

Options (cost extra):
Remote operator unit, copy unit, cables for the units, Dynamic braking unit, braking resistor, AC reactor, DC reactor, noise filter

FEATURES:

Precise Torque Regulation using Sensorless Vector Control
The torque calculation software (sensorless vector control) developed by Polyspede ensures accurate torque control throughout the entire frequency range, even with general purpose motors.

  • High starting PID control provided as standard 16-stage multi speed operation
  • Instantaneous power failure retry (frequency stabilization)
  • Intelligent terminal system allows you to select only the necessary functions from a full lineup of enhanced functions.
  • FAN ON/OFF selection to provide longer cooling fan life
  • Incorporated rush current prevention circuit torque of 200% or more (3.7kW-: 180% or more)
  • 100% continuous operating torque within a 1: 10 speed range (6 to 60 Hz/5 to 50 Hz) without motor de-rating. (3.7kW-: 1:3 (20-60Hz)

Advance Functions Condensed in One Unit

  • Auto tuning to set motor constants
  • Second motor setting (Provision to set second motor constants)

Perfect Matchingto Constant Torque Load

The powerful and intelligent SJ100 inverter series solves your applications requirements for high torque at low speeds.
(Regenerative braking circuit incorporated as standard) CONVEYOR TRUCK EXTRUDER MIXER LIFE etc. Simple Operation by Keypad or Terminal

The PSV6 can be started by pushing the RUN button or selection of a terminal mode. Speed can be changed by standard potentiometer, keypad or external signal. Functions are grouped for quick, easy settings.

Compact Size Saves Space

Installation space is reduced by 56% from the J100 series and 11% from the compact L50 series.

Network Compatible World Standard Machine Expands Global Business

The PSV6 Series of world standard machines provide global performance. European low-voltage directive compliant, EMC directive compliant (withdedicated noise filter)
UL, C-UL standards C-tick (Australian EMC requirements, with dedicated noise filter). The line-up is compatible with DEVICE NET, PROFIBUS, etc. with network options.

Menu Title